{"id":32976,"date":"2024-08-30T11:46:34","date_gmt":"2024-08-30T10:46:34","guid":{"rendered":"https:\/\/www.hawkins.biz\/?post_type=insight&#038;p=32976"},"modified":"2025-08-06T17:05:41","modified_gmt":"2025-08-06T16:05:41","slug":"behaviour-of-bolted-steel-connections-during-fires","status":"publish","type":"insight","link":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/","title":{"rendered":"Behaviour of Bolted Steel Connections During Fires"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"32976\" class=\"elementor elementor-32976\" data-elementor-post-type=\"insight\">\n\t\t\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-e040bd2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"14635\" data-id=\"e040bd2\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e25b8b4\" data-eae-slider=\"56469\" data-id=\"e25b8b4\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3096c14 elementor-widget elementor-widget-text-editor\" data-id=\"3096c14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bolts are critical components in structural steel connections that effectively govern their performance, particularly during fires where robustness becomes an important factor. In this article we explore the fundamental ways in which bolted connections can fail and some of the options available to achieve better performance.<\/p><h4><span style=\"color: #007aa3;\">Background\u00a0<\/span><\/h4><p>During a fire, the ability of the beam elements in a structure to develop catenary action is largely governed by the rotational capacity and strength of their connections. Investigations carried out on different connection configurations have shown that their failure temperature can be increased by avoiding the premature failure of the bolts.<\/p><p>There exists a substantial body of research that focuses on specific aspects of bolt assembly performance at ambient temperatures (e.g. friction between mating threads, nut tolerance class, number of threads in the grip, pretension force, etc.). This work underpins the current international design regulations. At elevated temperatures the picture is substantially less complete, with many of these parameters remaining unevaluated.<\/p><p>Prior to 1995, national design standards did not assess the behaviour of steel joints under fire conditions because the thermal mass of the joint area is much greater than that of the incoming structural members. However, observations from full-scale fire tests have subsequently shown that steel connections occasionally fail at elevated temperatures, particularly their tensile components.<\/p><h4><span style=\"color: #007aa3;\">Bolt Assembly Failure Modes<\/span><\/h4><p><strong>Applied tension forces<\/strong><\/p><p>There are two dominant tensile failure modes at elevated temperatures: <strong>necking failure<\/strong> and <strong>stripping failure<\/strong>. The former is a ductile failure mode due to substantial plastic deformation occurring in the bolt shank (typically in the threaded part). Stripping failure occurs when the engaged threads experience large shear deformations that eventually result in the nut disengaging and often occurs in a brittle mode. Necking failure is preferred in practice as it provides a ductile connection with appreciable rotational capacity.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-514ef7e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"12855\" data-id=\"514ef7e\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-28d2ffb\" data-eae-slider=\"96755\" data-id=\"28d2ffb\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4cb2f6a elementor-widget elementor-widget-image\" data-id=\"4cb2f6a\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"360\" height=\"159\" src=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture2.png\" class=\"attachment-large size-large wp-image-32980\" alt=\"A diagram showing bolts under tensile force.\" srcset=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture2.png 360w, https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture2-300x133.png 300w\" sizes=\"(max-width: 360px) 100vw, 360px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: Bolts under tensile force:  (a) terminology; (b) high ductility; (c) moderate ductility; (d) brittle fracture; (e) stripping failure.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-f990e11 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"65686\" data-id=\"f990e11\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-da7e47b\" data-eae-slider=\"5430\" data-id=\"da7e47b\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-de623ec elementor-widget elementor-widget-text-editor\" data-id=\"de623ec\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In most practical applications, <strong>partially-threaded<\/strong> and <strong>fully-threaded<\/strong> bolts are the most widely used. Partially-threaded bolts have a grip length below the bolt head free of threads while fully-threaded bolts have threads that run from just under the head all the way to the tip. Stripping failure results in the complete loss of bolt tensile strength, thus certain precautions should be considered to reduce the likelihood of this mode of failure. For partially-threaded bolts this can be achieved by using a nut with tighter tolerance class or a nut with higher class property. Additionally, the strengths of the bolt and the nut threads should be similar as it is shown that differences can result in the stripping of low strength threads. For fully-threaded bolts, stripping failure is highly likely to occur even with these precautions; avoiding stripping failures in this context is the subject of ongoing research.<\/p><p>The use of coatings, are essential for protecting high strength bolts in corrosive environments, such as offshore installations. However, such coatings and finishes can lower the coefficient of friction between mating threads at elevated temperatures, increasing the propensity of a stripping failure. This is due to the protective coatings having a lower melting point than the parent material of the bolts. A common coating is zinc which melts completely at 420\u00b0C. As such, the use of coated bolts at temperatures exceeding half the melting point of the coating is not recommended. It is also noted that molten coatings are a primary cause of liquid metal embrittlement. One feasible solution is to use material that has inherent-corrosion resistant characteristics such as stainless steel.<\/p><p><strong>Applied shearing forces\u00a0<\/strong><\/p><p>Failure of shear connections at elevated temperatures can occur in various ways, including the shear failure of the bolts, bearing failure of the plate against the bolts, and rupture of the plates. Shearing forces typically result in brittle failure modes at ambient temperatures, however tests have shown that the ductility of shear connections increases at elevated temperatures. Whilst stripping failure is not commonly observed in shear connections, tension forces arising due to plate prying action have been observed. Thus, bolts under shear may experience considerable tensile forces depending on the connection configuration and flexibility of the connected plates, which can reduce the shear capacity of the bolt due to a combined stress effect.<\/p><p><strong>Metallurgical failures\u00a0<\/strong><\/p><p>There are numerous <a href=\"https:\/\/www.hawkins.biz\/expertise\/materials-chemistry-biology\/metallurgy\/\" target=\"_blank\" rel=\"noopener\">metallurgical failure<\/a> modes including corrosion (general, pitting and crevice), stress corrosion cracking, galvanic corrosion, <strong>liquid metal embrittlement<\/strong>, <strong>temper embrittlement<\/strong>, and <strong>hydrogen embrittlement<\/strong>. The latter three types are particularly affected by elevated temperatures.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-ec809f7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"77494\" data-id=\"ec809f7\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-03e3f22\" data-eae-slider=\"77769\" data-id=\"03e3f22\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a89d569 elementor-widget elementor-widget-image\" data-id=\"a89d569\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"483\" height=\"176\" src=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture3.png\" class=\"attachment-large size-large wp-image-32981\" alt=\"Diagram showing metallurgical failures\" srcset=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture3.png 483w, https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture3-300x109.png 300w\" sizes=\"(max-width: 483px) 100vw, 483px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2: Metallurgical failures: (a) intergranular failure (brittle fracture); (b) crack propagation along grain boundaries for intergranular failure; (c) hydrogen bubbles along grain boundaries.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-5f81a4d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"41403\" data-id=\"5f81a4d\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2b5c900\" data-eae-slider=\"26530\" data-id=\"2b5c900\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a2946ef elementor-widget elementor-widget-text-editor\" data-id=\"a2946ef\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Liquid metal embrittlement<\/strong> (LME) failure is due to the instability of platings and coatings at high temperatures. LME of galvanized steel bolts occur when there is a simultaneous application of stress and high temperature. A surface layer of liquid zinc is present and when a tensile stress sufficient to cause surface cracks is applied to a galvanised steel bolt, the liquid zinc flows into the crack tips. This weakens the cohesion of grain boundaries, enabling the cracks to propagate easily into the steel matrix as seen in Figure 2(a) above. Accordingly, the bolt then fails instantly in a brittle manner.<\/p><p><strong>Temper embrittlement<\/strong> (TE) is an intergranular failure caused by the reduction of the cohesion along grain boundaries, ultimately leading to a brittle failure mode; Fig 2(b). It is a characteristic failure for alloy steels that are tempered or heated in the range of 375\u2212575<span style=\"letter-spacing: normal; color: var( --e-global-color-text ); background-color: initial;\">\u00b0C<\/span><span style=\"color: var( --e-global-color-text ); letter-spacing: -0.4px; background-color: initial;\">\u00a0and then continuously cooled at a slow cooling rate. The susceptibility of bolts to fail by TE is also affected by the alloying elements. In particular, the most widely used alloying elements such as nickel, manganese, and chromium, enhance TE failure. When bolts containing these alloying elements are exposed to elevated temperatures in this range and then continuously cooled, they may still be susceptible to brittle failure even if the bolt strength has not been affected. Thus, despite it being well-documented in the literature that the ductility of the bolt increases with increasing temperature, TE shifts the ductile-to brittle transition temperature to a significantly higher temperature, which can result in a brittle failure during a fire event.<\/span><\/p><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6438ad1 elementor-widget elementor-widget-text-editor\" data-id=\"6438ad1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>High strength bolts are susceptible to failure by <a href=\"https:\/\/www.hawkins.biz\/insight\/hydrogen-embrittlement-how-can-a-gas-make-a-metal-brittle\/\" target=\"_blank\" rel=\"noopener\"><strong>hydrogen embrittlement<\/strong><\/a> (HE). A source of hydrogen is required for HE to occur, which can be secured during the zinc electroplating process for galvanised high strength bolts or exposure to elevated temperatures in hydrogen containing environments. The tensile capacity and ductility of the high strength bolts significantly deteriorates due to the pressure exerted by the hydrogen bubbles that form on the metal grains as seen in Figure 2(c). The bubbles result in the formation of microcracks that grow and propagate with or without externally applied loads, with eventual failure occurring anywhere between hours or years after the bolt was first fabricated.<\/p><h4><span style=\"color: #007aa3;\">Fire Effects on Bolted Connections<\/span><\/h4><p><strong>Thermal loading<\/strong><\/p><p>The damage to a steel bolted connection is largely controlled by how much heat is absorbed by its components. Predicting the extent of this thermal loading is challenging due to both the relative complexity of connection assemblies and the difficulties arising from modelling the heat source. The high thermal conductivity of steel ensures a high degree of heat transfer from the fire to the connection components. However, due to the relatively high mass concentration at the joint and the presences of gaps between plates, connection assemblies typically exhibit an uneven temperature distribution. Moreover, the fire location with respect to the connection is important for accurate thermal analysis, considering that the heat transfer is mainly radiative when the fire reaches its peak value.<\/p><p>The forces that develop in bolts during a fire depend on the type of connection and the fire phase (heating or cooling). Figure 3 illustrates the typical forces on bolts during the heating and cooling phases for moment and shear beam-to-column connections. For moment connections, the tensile force in the bolts tends to reduce with increasing temperature due to the incoming beam undergoing expansion and exerting an opposing compressive force on the connection. For shear connections on the other hand, the force on the bolts tends to increase with the temperature, providing that the gap between the beam and the column flange is larger than the beam elongation during fire. Thus, the bolts in connections designed to carry only shear are more vulnerable to failure during the heating phase and before developing catenary action. In some scenarios, other factors such as the elongation of the bolt holes within the beam web and an increase of the bolt ductility with temperature may improve the connection shear behaviour.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-a70e008 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"64070\" data-id=\"a70e008\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9c3cff7\" data-eae-slider=\"49812\" data-id=\"9c3cff7\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-877440f elementor-widget elementor-widget-image\" data-id=\"877440f\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"225\" height=\"197\" src=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Capture.jpg\" class=\"attachment-large size-large wp-image-32992\" alt=\"A diagram of a typical axial temperature response during and after a fire.\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3a: Typical axial temperature response during and after a fire.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-1a69f6a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"18934\" data-id=\"1a69f6a\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b199fe5\" data-eae-slider=\"84972\" data-id=\"b199fe5\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fa66e98 elementor-widget elementor-widget-image\" data-id=\"fa66e98\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"488\" height=\"191\" src=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture5.png\" class=\"attachment-large size-large wp-image-32993\" alt=\"\" srcset=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture5.png 488w, https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture5-300x117.png 300w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3b: Bolt forces during and after a fire for moment connections.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-1924bc4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"61244\" data-id=\"1924bc4\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1207527\" data-eae-slider=\"55366\" data-id=\"1207527\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8751219 elementor-widget elementor-widget-image\" data-id=\"8751219\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"485\" height=\"171\" src=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture6.png\" class=\"attachment-large size-large wp-image-32994\" alt=\"\" srcset=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture6.png 485w, https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture6-300x106.png 300w\" sizes=\"(max-width: 485px) 100vw, 485px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3c: Diagram showing bolt forces during and after a fire for shear connections.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-b2eb80d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"78595\" data-id=\"b2eb80d\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f1e3598\" data-eae-slider=\"6159\" data-id=\"f1e3598\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7be0c65 elementor-widget elementor-widget-text-editor\" data-id=\"7be0c65\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>If the fire is extinguished prior to any connection failure, the contraction of the steel beam during the cooling phase results in considerable tensile forces developing in the connection and the bolt. Whilst it is arguable that the full bolt strength is restored as the temperature decreases, this is based upon the incorrect assumption that the residual strength of high strength bolts is reversible because of cooling. However, the residual strength of bolts depends upon various factors including the maximum attained temperature, the duration of the fire, and the cooling rate, all of which ultimately control the metallurgical phase transformation. This frequently results in a significant reduction in bolt capacity even after the fire is extinguished.<\/p><p><strong>Effect of bolt failures on connection performance<\/strong><\/p><p>Experimental work carried out on moment-resisting beam-to-column connections has shown that bolt stripping results in a premature failure of the connection, significantly compromising its rotational capacity, which is important for developing catenary action. In tests it has been observed that premature connection failures by stripping can occur at a rotation of 1.5\u00b0; when stripping failure is avoided (e.g. by using a double nut bolt configuration) the rotation capacity increases to approximately 7\u00b0. For shear connections, researchers have observed that the failure mode transitions from plate bearing at ambient temperatures to bolt shear at temperatures beyond 500\u00b0C.<\/p><h4><span style=\"color: #007aa3;\">Final Remarks and Summary<\/span><\/h4><p>The structural fire performance of bolts is a complicated subject with limited formal guidance being available in British and European codes and standards (Eurocode 3 Part 1.8). These rules provide simple temperature-dependent reduction factors, but they do not consider modes of failure. Additionally, special bolt grades (e.g. high strength) and <a href=\"https:\/\/www.hawkins.biz\/expertise\/materials-chemistry-biology\/\" target=\"_blank\" rel=\"noopener\">materials<\/a> (e.g. stainless) are available for use at ambient temperatures, but these are not yet accounted for in current design rules. In summary:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-5be1db1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"4611\" data-id=\"5be1db1\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-298e286\" data-eae-slider=\"14518\" data-id=\"298e286\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1b3931f elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"1b3931f\" data-element_type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-right\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M285.476 272.971L91.132 467.314c-9.373 9.373-24.569 9.373-33.941 0l-22.667-22.667c-9.357-9.357-9.375-24.522-.04-33.901L188.505 256 34.484 101.255c-9.335-9.379-9.317-24.544.04-33.901l22.667-22.667c9.373-9.373 24.569-9.373 33.941 0L285.475 239.03c9.373 9.372 9.373 24.568.001 33.941z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">There are two predominant modes of bolted connection failure at elevated temperatures: stripping and necking.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-right\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M285.476 272.971L91.132 467.314c-9.373 9.373-24.569 9.373-33.941 0l-22.667-22.667c-9.357-9.357-9.375-24.522-.04-33.901L188.505 256 34.484 101.255c-9.335-9.379-9.317-24.544.04-33.901l22.667-22.667c9.373-9.373 24.569-9.373 33.941 0L285.475 239.03c9.373 9.372 9.373 24.568.001 33.941z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Necking failure is a ductile failure mode and is desired  as this promotes a robust connection capable of sustaining the tensile forces that develop from the beams acting as catenaries during a fire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-right\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M285.476 272.971L91.132 467.314c-9.373 9.373-24.569 9.373-33.941 0l-22.667-22.667c-9.357-9.357-9.375-24.522-.04-33.901L188.505 256 34.484 101.255c-9.335-9.379-9.317-24.544.04-33.901l22.667-22.667c9.373-9.373 24.569-9.373 33.941 0L285.475 239.03c9.373 9.372 9.373 24.568.001 33.941z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Partially threaded bolts are less susceptible to stripping failure than fully threaded bolts.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-right\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M285.476 272.971L91.132 467.314c-9.373 9.373-24.569 9.373-33.941 0l-22.667-22.667c-9.357-9.357-9.375-24.522-.04-33.901L188.505 256 34.484 101.255c-9.335-9.379-9.317-24.544.04-33.901l22.667-22.667c9.373-9.373 24.569-9.373 33.941 0L285.475 239.03c9.373 9.372 9.373 24.568.001 33.941z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Care should be taken when specifying bolts with special coatings, such as zinc, in fire critical regions of a structure.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-right\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M285.476 272.971L91.132 467.314c-9.373 9.373-24.569 9.373-33.941 0l-22.667-22.667c-9.357-9.357-9.375-24.522-.04-33.901L188.505 256 34.484 101.255c-9.335-9.379-9.317-24.544.04-33.901l22.667-22.667c9.373-9.373 24.569-9.373 33.941 0L285.475 239.03c9.373 9.372 9.373 24.568.001 33.941z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">After a fire, a bolt may not exhibit the same material characteristics as it did prior to the fire.  Furthermore, significant stresses may remain locked into the connection due to permanent deformations in the connected structural components. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"has_eae_slider elementor-section elementor-top-section elementor-element elementor-element-36c0f9d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-eae-slider=\"18119\" data-id=\"36c0f9d\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"has_eae_slider elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b06c392\" data-eae-slider=\"26167\" data-id=\"b06c392\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-76b7ccd elementor-widget elementor-widget-text-editor\" data-id=\"76b7ccd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><p><strong>Further reading\u00a0<\/strong><\/p><p>Behaviour of stainless and high strength steel bolt assemblies at elevated temperatures\u2014A review.<br \/>MA Shaheen, ASJ Foster, LS Cunningham, S Afshan<br \/>Fire Safety Journal 113, 102975<\/p><p>A numerical investigation into stripping failure of bolt assemblies at elevated temperatures.<br \/>MA Shaheen, ASJ Foster, LS Cunningham, S Afshan<br \/>Structures 27, 1458-1466<\/p><p>Performance of axially restrained carbon and stainless steel perforated beams at elevated temperatures.<br \/>MA Shaheen, S Afshan, ASJ Foster<br \/>Advances in Structural Engineering 24 (15), 3564-3579<\/p><p>Bolt stripping failure and ductility of end plate beam-column connections at ambient and elevated temperatures.<br \/>MA Shaheen, LS Cunningham, ASJ Foster<br \/>Journal of Structural Fire Engineering 14 (2), 167-184<\/p><p>Selecting Suitable Bolt Parameters to Achieve Ductility at Elevated Temperatures.<br \/>MA Shaheen, ASJ Foster, LS Cunningham, S Afshan<br \/>ce\/papers 4 (2-4), 1191-1195<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>In this article we explore the fundamental ways in which bolted connections can fail and some of the options available to achieve better performance.  <\/p>\n","protected":false},"featured_media":32977,"parent":0,"template":"","insight_category":[],"experties":[62,65,66,68],"class_list":["post-32976","insight","type-insight","status-publish","has-post-thumbnail","hentry","experties-built-environment","experties-engineering","experties-fire-explosions","experties-materials-chemistry-biology"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Bolted Steel Connections in Fires<\/title>\n<meta name=\"description\" content=\"Explore how bolted steel connections behave during fires, including failure modes and design improvements for structural resilience.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Bolted Steel Connections in Fires\" \/>\n<meta property=\"og:description\" content=\"Explore how bolted steel connections behave during fires, including failure modes and design improvements for structural resilience.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/\" \/>\n<meta property=\"og:site_name\" content=\"Hawkins Forensic Investigation\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-06T16:05:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"427\" \/>\n\t<meta property=\"og:image:height\" content=\"278\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/\",\"url\":\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/\",\"name\":\"Bolted Steel Connections in Fires\",\"isPartOf\":{\"@id\":\"https:\/\/www.hawkins.biz\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png\",\"datePublished\":\"2024-08-30T10:46:34+00:00\",\"dateModified\":\"2025-08-06T16:05:41+00:00\",\"description\":\"Explore how bolted steel connections behave during fires, including failure modes and design improvements for structural resilience.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#primaryimage\",\"url\":\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png\",\"contentUrl\":\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png\",\"width\":427,\"height\":278,\"caption\":\"A bolted steel connection.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hawkins.biz\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Insights\",\"item\":\"https:\/\/www.hawkins.biz\/insight\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Behaviour of Bolted Steel Connections During Fires\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hawkins.biz\/#website\",\"url\":\"https:\/\/www.hawkins.biz\/\",\"name\":\"Hawkins Forensic Investigation\",\"description\":\"Specialising in Forensic Investigation\",\"publisher\":{\"@id\":\"https:\/\/www.hawkins.biz\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hawkins.biz\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.hawkins.biz\/#organization\",\"name\":\"Hawkins and Associates\",\"url\":\"https:\/\/www.hawkins.biz\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.hawkins.biz\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2022\/03\/logo_svg.svg\",\"contentUrl\":\"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2022\/03\/logo_svg.svg\",\"width\":164,\"height\":61,\"caption\":\"Hawkins and Associates\"},\"image\":{\"@id\":\"https:\/\/www.hawkins.biz\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/hawkins-and-associates-limited\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Bolted Steel Connections in Fires","description":"Explore how bolted steel connections behave during fires, including failure modes and design improvements for structural resilience.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/","og_locale":"en_GB","og_type":"article","og_title":"Bolted Steel Connections in Fires","og_description":"Explore how bolted steel connections behave during fires, including failure modes and design improvements for structural resilience.","og_url":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/","og_site_name":"Hawkins Forensic Investigation","article_modified_time":"2025-08-06T16:05:41+00:00","og_image":[{"width":427,"height":278,"url":"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/","url":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/","name":"Bolted Steel Connections in Fires","isPartOf":{"@id":"https:\/\/www.hawkins.biz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#primaryimage"},"image":{"@id":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png","datePublished":"2024-08-30T10:46:34+00:00","dateModified":"2025-08-06T16:05:41+00:00","description":"Explore how bolted steel connections behave during fires, including failure modes and design improvements for structural resilience.","breadcrumb":{"@id":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#primaryimage","url":"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png","contentUrl":"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2024\/08\/Picture1-1.png","width":427,"height":278,"caption":"A bolted steel connection."},{"@type":"BreadcrumbList","@id":"https:\/\/www.hawkins.biz\/insight\/behaviour-of-bolted-steel-connections-during-fires\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hawkins.biz\/"},{"@type":"ListItem","position":2,"name":"Insights","item":"https:\/\/www.hawkins.biz\/insight\/"},{"@type":"ListItem","position":3,"name":"Behaviour of Bolted Steel Connections During Fires"}]},{"@type":"WebSite","@id":"https:\/\/www.hawkins.biz\/#website","url":"https:\/\/www.hawkins.biz\/","name":"Hawkins Forensic Investigation","description":"Specialising in Forensic Investigation","publisher":{"@id":"https:\/\/www.hawkins.biz\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hawkins.biz\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.hawkins.biz\/#organization","name":"Hawkins and Associates","url":"https:\/\/www.hawkins.biz\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.hawkins.biz\/#\/schema\/logo\/image\/","url":"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2022\/03\/logo_svg.svg","contentUrl":"https:\/\/www.hawkins.biz\/wp-content\/uploads\/2022\/03\/logo_svg.svg","width":164,"height":61,"caption":"Hawkins and Associates"},"image":{"@id":"https:\/\/www.hawkins.biz\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/hawkins-and-associates-limited\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/insight\/32976","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/insight"}],"about":[{"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/types\/insight"}],"version-history":[{"count":119,"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/insight\/32976\/revisions"}],"predecessor-version":[{"id":40797,"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/insight\/32976\/revisions\/40797"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/media\/32977"}],"wp:attachment":[{"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/media?parent=32976"}],"wp:term":[{"taxonomy":"insight_category","embeddable":true,"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/insight_category?post=32976"},{"taxonomy":"experties","embeddable":true,"href":"https:\/\/www.hawkins.biz\/wp-json\/wp\/v2\/experties?post=32976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}